Oxair Gases

Home Up About

Process Series

 

The Process Series are designed for medium to high oxygen flows and unattended operation.  The process has optimised bed sizings for reduced power consumption.

Some clients install two process series generators rather than a single Tonnage system.


These three OA-1500 units are used in a Water Treatment facility feeding Ozone generation units.  Each unit produces 42.5 sm3/hr (1500 scfh) of Oxygen.

 

 

                                
                                            This OA-2000 unit is used in Mineral
                                            Leaching, and produces 56.6 Sm3/hr
                                            (2000 scfh) of Oxygen.

                                            Oxygen generators are fabricated up to
                                            113 Sm3/hr in this configuration.

 

 

MODEL

SCFH

Sm3/hr

Oxygen Flowrate Nm3/hr

Contained Oxygen
kg/hr @ 90%

Air (m3/min) (Dry)

Air (scfm) (Dry)

Receiver (min)

OA-750

750

21.2

19.7

25.9

4.10

145

1000 L

OA-1000

1000

28.3

26.2

34.5

5.95

210

1250 L

OA-1100

1100

31.1

28.8

38.0

6.55

231

1250 L

OA-1250

1250

35.4

32.8

43.2

7.44

263

1500 L

OA-1500

1500

42.5

39.3

51.8

8.93

315

2000 L

OA-1750

1750

49.6

45.9

60.4

10.41

368

2250 L

OA-2000

2000

56.6

52.4

69.1

11.90

420

2500 L

OA-2500

2500

70.8

65.6

86.3

14.88

525

3000 L

OA-3000

3000

84.9

78.7

103.6

17.85

630

4000 L

OA-3500

3500

99.1

91.8

120.9

20.83

735

4500 L

OA-4000

4000

113.3

104.9

138.1

23.80

840

5000 L

  1. Models larger than the OA-4000 are designed and built to customer requirements.
  2. Gas is measured at 1 atmosphere and 0°C.
  3. Standard Oxygen Pressure is 310 kPag (45psig).

 

GENERAL SCOPE OF SUPPLY

The following outlines the general scope of supply for all standard oxygen PSA generator packages from Oxair Gases Pty Ltd. The following scope of supply is subject to change depending of the options chosen.

  • Proprietary Oxygen PSA Generator by Oxair Gases.
  • PSA System Control Panel – Complete with alarms.
  • Feed Air Compressor – Rotary Screw.
  • Feed Air Dryer Refrigerated dryer for 3°C pressure dew point, with alarm.
  • Inlet Air Filtration – 4 Stage package for the removal of water, oil and sieve pretreatment. Also includes Differential Pressure Alarm.
  • Oxygen Booster Pack – If the required oxygen pressure is greater than 350 kPag. Includes dual boosters, high pressure O2 vessel, and interconnecting pipework.
  • Feed Air Buffer Vessel.
  • Low Pressure Oxygen Vessel.
  • Oxygen Outlet Pressure Regulator.
  • Interconnecting Pipework.

 

Small Series Cabinet Series Process Series Tonnage Series

 
Send mail to craigm@oxair.com.au with questions or comments about this web site.
Copyright © 2001 Oxair Gases Pty Ltd