Small Series

 

These oxygen generators are currently under development and final testing.  They will be available with and without integral air compressor.  Oxygen flow rates will be as per the following table:

MODEL

SCFH

Sm3/hr

Oxygen Flowrate Nm3/hr

Contained Oxygen
kg/hr @ 90%

Air (m3/min) (Dry)

Air (scfm) (Dry)

Oxygen Receiver

OA-5S

5

0.14

0.13

0.17

0.09

3

5 L

OA-5SC

5

0.14

0.13

0.17

Inc

Inc

5 L

OA-10S

10

0.28

0.26

0.34

0.12

4

5 L

OA-10SC

10

0.28

0.26

0.34

Inc

Inc

5 L

OA-15S

15

0.42

0.38

0.51

0.12

4

5 L

OA-15SC

15

0.42

0.38

0.51

Inc

Inc

5 L

OA-20S

20

0.57

0.52

0.69

0.15

5

30 L

OA-20SC

20

0.57

0.52

0.69

Inc

Inc

Inc

OA-35S

35

0.99

0.92

1.21

0.21

7

45 L

OA-35SC

35

0.99

0.92

1.21

Inc

Inc

Inc

  1. Gas is measured at 1 atmosphere and 0°C.
  2. Standard Oxygen Pressure is 310 kPag (45psig).
  3. Intermediate or OEM capacities available on request.

 

Small Series Cabinet Series Process Series Tonnage Series

 